Power vs Time Sequence consists of Power vs Time Segments for an
Auxliary Power Module (APM)
axis.
The Sequence form illustrates all the segments within the cycle,
referred to as the sequence of an axis. To coordinate between
the timing of other axes, you may chart up to 6 profiles, from any
axis, using the Configure Profiles form.
Select a Segment, then click Edit at the top left of the form,
or right-click on the selected step, and then select Insert, Append
or Delete. How to insert a segment before Step 111 is
shown below.
The Split Segment feature splits the selected segment into N
equal segments that equal the total duration of the original
segment.
To split a segment, select one segment, then right-click
and select "Selection > Split Segment", and
specify the number of segments.