Höhepunkten der neuen Eigenschaften und Erweiterungen.
Für alle Details verweisen wir auf unser Revision
Log.
- Linear Belt Actuators
- Added Linear Belt Actuator with all sizing considerations
including:
- Belt Max Tensile Load
- Cart Mass
- Mass Distance from Cart
- Max Load Limit Moment
- Load Max Limit
- Force vs Speed performance chart
- Added Mechanisms in
Parallel (n>1) support for
- Linear Belt Actuator
- Conveyor
- Spooler Hanging Load
- The Winder Spooler (aka Winch) is extended with a Hanging
Load.
- A dynamic model, considering each layer wrap of material and
the changing hanging load of material.
- The Spooler Hanging Load is available for both the Winder Center & Winder Surface Driven mechanisms.
- Sequence form
- When the Rated profile is displayed, the rated profile is
shaded in the "margin" area underneath. Eg. If the Motor Peak
Torque Margin = 10%, then the motor Tmax rated profile is drawn
with a shaded region 90-100% of Tmax. This helps users see how
close the application profiles are to the user specified
margin.
- When a Winder Spooler, now display the Spooler as a second
dynamic image when the chart crosshairs are selected
- Chart Profiles
- Added Bleeder/Chopper Current Profile to Sequence chart
- Added Inverter Output Frequency [fHz] profile to Sequence
chart
- Changed Ixt legend display to Ixt0, Ixt1, Ixt2 and same for
Pxt0, Pxt1, Pxt2
- Motor [Vz] profile
- Now also draw the actual [Vz] profile, which is helpful to see
if the Motor.Vz > Drive.Vz0, as well as helpful to isolate
if/when Motor.Vz > Drive.Vz during Backup Power Mode
- Import Sequence
- Added Scale Factor drop down lists (1 or -1) for the Thrust and
Torque/Force vector columns, providing the option to invert all
values in each column when ScaleFactor = -1
- When imporing a Sequence, now when the number of segments
exceeds the maximum allowed, the source data is "down sampled" by
taking every nth segment to fall under the allowed maximum
- When importing an Import Trace, the maximum samples allowed is
2000. When the source data exceeds the maximum allowed, the source
data is "down sampled" by taking every nth segment to fall under
the allowed maximum
- When opening KB Sequence, no longer use MsgBox, instead display
at top of the form "Kinetic Buffer: All sequence edit functions
disabled"
- When opening APM Sequence defined by another PG, no longer use
MsgBox, instead display at top of the form "Sequence cannot be
changed because it is defined by PGx. All edit functions
disabled."
- Added Profile Type Sinusoidal2 and Move Rules 1/5
& 1/10
- Added new profile type "Sinusoidal2
- Added 1/5 & 1/10 motion rules for all profile types
- The 1/2 & 1/3 rule buttons are now changed to a drop-down
list to accommodate all rules.
- The 1/5 and 1/10 rules are especially helpful in applications
where the move is defined as Time/Distance and the max velocity is
calculated while maintaining the motion rule.
- Conveyor Mechanism
- Added support for multiple mechanisms in parallel
- Added inputs to align with new Linear Belt Actuator mechanism
- Cart Mass
- Mass Distance From Cart
- Max Load Limit
- Moment Load Max Limit
- Added Force vs Speed performance chart
- Ball Screw Mechanism
- When Screw is rotating and the Nut is moving linearly, now the
screw output force is transmitted through the mechanism as an Axial
force as an Axial Load on the gearbox output bearing. This is
helpful in sizing gearboxes in hexapods with electromechanical
linear actuators/ ball screws. The axial forces of the ball screws
are supported by the gearbox bearings.
- Rack & Pinions
- Added Stober Rack & Pinion Sizing Rules
- Added [P_Typ1] field in RacksPinionsFeedForce table, which adds
support for the Pinion Input Type [P_Typ1] as part of the
combination variables that determines the Rack & Pinion
FMax.
- Rack & Gearbox Pinion Mechanism form
- Under the Limits tab, now display Gearbox Pinion Nominal Force,
and Rack & Pinion Max Force and Max-Stop Force
- Rack & Gearbox Pinion performance
- Add drop down list to view only the "Gearbox" or "Rack &
Pinion" as well as the complete combined product "Rack &
Gearbox Pinion"
- Motor Linear Actuator performance
- Add drop down list to view only the "Motor" or "Linear
Actuator" as well as the complete combined product "Motor Linear
Actuator"
- Position Based Load
- Added Thrust and Torque scale factors
- Motor Model
- Motor I2t Model Low-Speed De-rating
- Added motor I2t low-speed de-rating when the motor's electrical
frequency <= 5Hz
- The I2t model de-rates the rated torque starting at 0rpm with
Io/SQRT(2), using an exponential model up to 5Hz
- The inhomogeneous heat dissipation region, is defined from 0rpm
up to [nh] where [nh] is calculated using 5Hz and the motor number
of pole pairs
- The same approach is used for Linear Motors except using the
pole width [m]
- PMSM
- Improved support for IPMSM with Ld<>0, which now includes
Reluctance Torque
- This part of the motor model is still noted as 'beta' as still
working with vendors to further refine the model
- Motor Database Selection form
- Gearbox Torque Based Efficiency using Efficiency Formula
- When the Formula [Eff_Frml] checkbox is enabled, the Gearbox
efficiency allows for a formula that can be a function of Input
Speed [n] and Output Torque [T], allowing for more accurate
efficiency modelling under different torque loads.
- The standard Efficiency vs Speed curve remains for backwards
compatibility and when Formula [Eff_Frml] is not used.
- Energy Storage Modules:
Added 'Droop Curve' Control Mode
- Added 'Droop Curve' in addition to the existing 'Voltage
Threshold' control.
- The Droop Curve configurable parameters appear in a drop-down
added at the top of the Power vs Time form.
- The Droop Curve defines the control characteristics for the ESM
defining the relationship between the DC Bus Voltage [Vz] and
Current [Iz].
- Worth noting in the database
- Changed Capacitance field name from [C] to [Cc] to clarify
capacitance on the ESM capacitor side
- Added a new field [Cz], for capacitance on the DC Bus, allowing
for ESMs that have capacitance on the DC Bus side
- Enhanced DC Bus Modelling where [Vz] Dips in Normal Mode
- In Normal mode, when Supply Peak Power
Optimization (Pro version) is enabled, the DC Bus
Voltage [Vz] is allowed to drop below the Nominal Bus Voltage
[Vz0].
- Applies in all cases, with or without an ESM and/or KB on the
DC Bus.
- But why is [Vz] allowed to drop only when Supply Peak Power
Optimization is enabled?
- Because something must "give".
- When Supply Peak Power Optimization is enabled, the peak power
limit of each Infeed Module "holds", and any additional power comes
from the DC Bus, and then [Vz] decreases.
- When Supply Peak Power is disabled, then [Vz] "holds" at [Vz0]
and then any additional power comes from Infeed Module.
- Enhanced DC Bus Modelling
where [Vz] Dips in Backup Power Mode
- In Backup Power mode, the DC Bus voltage [Vz] is allowed to
drop after the ESM and/or KB run out of energy.
- Previously in v4.5 and ealier, once the ESM and/or KB ran out
of energy, Backup Power mode stopped and did not continue to run
down the DC Bus.
- Now with the added capability, there are 3 tiers of backup
power - ESM, KB and then the DC Bus CM bank.
- Note this applies if Supply Peak Power Optimization is enabled
or disabled since the Mains Supply is gone in Backup Power
mode.
- Optimizer: Suggested Paramaters
& Other Enhancements
- Now list suggested parameters before applying them, allowing
the user to see the parameters clearly before all the fields are
populated
- Added "Supply Peak Power" & "Supply Cont Power"
optimization targets for Single Axis Optimization
- Improved handling of Additional Constraints allowing the
Optimizer to work through "tough" Additional Constraints and not
"give up" too quickly
- Additional Constraints
- Added Mechanism Utilization Constraint used for Master Axis
Optimization
- Added Mechanism Constraints for
Max Torque/Force Margin and
Max Speed Margin
- Add/Edit Constraints
- Now Pre-fill initial values in the Min/Max textboxes when new
Additional Constraint type is selected of type Margin (10-100%) or
Utilization (90-100%)
- Infeed Modules
- Inverter Ixt Thermal Overload
Model
- Added Ixt_kFrml for each Ixt0, 1 & 2 in each Inverter PWM
Frequency, fs0, 1, 2 & 3
- Ixt_kFrml is applied to the Ixt Fast Slow model, using the
Inverter Output Frequency [fHz] and DC Bus Voltage De-rating [Vzdr]
variables
- Ixt_kFrml formula can be used at any frequency range
- System Check
- Added new Warning message when Vz < Vz0
- "Bus voltage [Vz] < Nominal bus voltage [Vz0]. Contact
vendor for approval"
- Conveyor
- Added message if Max Load is exceeded
- Added message if Moment Load Max is exceeded
- Ball Screw
- Now when "Total travel distance exceeded" alarm occurs, the
mechanism overall Utilization bar turns red (critical), but the
overall value is not changed
- Linear Actuator
- Now when "Total travel distance exceeds screw length" alarm
occurs, the mechanism overall Utilization bar turns red (critical),
but the overall value is not changed
- Conveyor
- Now when "Max travel limit exceeded" alarm occurs, the
mechanism overall Utilization bar turns red (critical), but the
overall value is not changed
- Linear Axis with Incline
- Improved messaging when Motor Brake is not enabled and the
application has a holding torque at standstill
- Rotary Axis with Unbalanced Load
- Added new message when an unbalanced load causing a holding
torque at standstill and the Motor Brake is not enabled
- Bill of Material
- Added additional values for ESM EMs including Vcmax, Imax &
Icont
- Print Report
- Print Config
- Added option to chart each Power Group's Power Chart using the
last chart configuration used in the Power vs Time Chart form
- Database
- Prevent Losing Add/Edit Product Data
- Added 'Database AutoBackup' feature to capture all product data
entered manually into the database using the Add/Edit forms
- Added multi-language support for [DocPath] urls
- Allows urls linking to product information can be language
dependent
-
- For example, if the active language is English, German or
Italian, then the resulting DocPath links are:
- www.companyname.com/en/drives/ProductABC.pdf
- www.companyname.com/de/antrieben/ProductABC.pdf
- www.companyname.com/it/azionamenti/ProductABC.pdf
- This is accomplished by defining Language Variables in the
Vendors database table under a new column named
[DocPathLangVars].
- License Activation Wizard
- Added back Email option to make a license request, now using a
web form that is pre-populated by the wizard
- Simply click 'Submit' button on the web form and the license
request is sent to the web server
- Requires Internet access by the License Activation Wizard
- Help
- Mechanism pages
- Updated and simplified all mechanism formulae
- Defined effiency and direction factor based on quadrant, then
consolidate formulae to one set for all quadrants
- Added Force/Torque vector to formulae
- Gearbox Efficiency
page
- Added new section explaining in the new Efficiency formula and
a very detailed example of how to create a formula using Excel and
its Trendline feauture
- Cart Mechanism
- Added section "Wheel No Slip Margin" explaining what it is and
its formula
- Energy Storage Solution
page
- Added 'Voltage Levels' section explaining the proper order of
voltage levels for proper ESM operation
- Added 'Supply Peak Power Optimization' link under the 'Bus
Modules > Energy Storage Solution' folder
- Optimizer
- Added Combined
Products page
- Supply Peak Power
Optimization (Pro version)
- Added option to add/subtract DC Bus [Cz] and/or ESS [Cess]
capacitance for quick scenario analysis
- Also added ability to find optimal [Cz] and/or [Cess] to
quickly find the optimal capacitance to minimize supply energy
- Added Mechanisms in
Parallel (n>1) support for
- Ball Screws
- Rack & Pinions
- Rack & Gearbox Pinions
- Two Pumps
- Motor Model
- The motor phase current [Iph] and power factor [PF] are changed
so that [Iph] is always positive, and the [PF] now changes to
negative when the motor is generating power back to the drive.
Previously, it was the other way around.
- All Feature sets
- Enabled [Iq] and [Id] phasors as option to display in Sequence
chart. Previously only enabled for Advanced & Pro
versions.
- Print Report
- Rack & Pinion mechanism now organizes Rack data under its
heading, and Pinion data under its heading
- Shade all affected cells when more than 1
mechanism/transformation/motor/drive in parallel. Ie. n>1.
- See Mechanisms in
Parallel: Print Report
- Max-Stop Mode
- In the Sequence form when in Max-Stop mode, select the
crosshairs and right-click and select
Start Max-Stop here to specify the
Max-Stop ramp for the active axis or all axes in the Power
Group
- Move form
- Extended profile type "Sub-Segment" to a fully flexible
Jerk-Linear-Jerk ramp segment
- Ie. Specify any portion of a standard Linear profile by
specifying the Jerk, Start & End Velocity and Start & End
Acceleration
- Previously, only the linear, Start Jerk ramp or End Jerk ramp
portion could be specified in one Sub-Segment
- This exteneded capability allows for a continuous spline using
a standard jerk profile without the need for polynomials
- PMSM Field Weakening UI
- For PMSMs, when the Motor FW curve is used, now display "FW"
beside the Bus Voltage value. If field weakening is applied to the
motor where the application profiles (green) cross over into the
shaded FW zone, the "FW" text is highlighted in pink, the same
colour as the pink shading of the motor FW zone in the chart. The
same display is also done in the Main form beside the bus voltage
drop down list.
- PMSM
- Added database field [Ld] "Stator d-axis inductance" for PM
salient machines
- Position Based Load
- Added ability to edit table data including add/delete rows,
edit cell values
- Applies to Rotary and Slider Crank mechanisms
- Slider Crank
- When motion defined at the Crank, added the option to specify
"360deg Modulo"
- Linear Mechanism forms
- Moved the Incline input under the "Load" tab
- Applies to Conveyor, Ball Screw, Rack & Pinion, Cart,
Slider Crank, etc.
- Ball Screw Mechanism
- Added Nut Roller Inertia input, used when the screw is rotating
and the nut is stationary
- Added Screw Dynamic Load Rating [Ca] as an input under the
Limits tab for a user-defined ball screw, thereby allowing for
liftetime calculations for a user-defined ball screw
- Added drop down list for suggested mechanism efficiency values
- Ball Screw: 95% (typ. 70-95%)
- Roller Screw: 90% (typ. 70-90%)
- Lead Screw: 65% (typ. 35-65%)
- Added the following parameters to the Ball Screw performance
data displayed on the Main form, consistent with the Performance
form and Print Report
- Equivalent dynamic load
- Stroke
- Lifetime (distance)
- Lifetime (cycles)
- Lifetime (hours)
- Add / Edit Rack & Pinion form
- Added buttons to list all Racks or Pinions using the same
combination parameters, along with the variables that are different
such as rack length
- For those vendors that publish Rack & Pinion product data,
this is a huge improvement that will help quickly isolate product
data issues.
- Command Line Interface
- Added the ability to set the Operating Mode in the command
line
- Command Line Print to
File
- Added the ability to set the Operating Mode in the command
line
- Database Utility
- Added extensive combinations checking for Racks, Pinions, FMax
database tables. For those vendors that publish Rack & Pinion
product data, this is a huge improvement that will help quickly
isolate product data issues
- Added check if [DocPath] field is numeric with message "Invalid
url". This will catch the scenerio where perhaps the [ProductZone]
value was mistakenly entered in the [DocPath] column.
- Help
- Overload Monitoring
- Added formulae for Infeed Pxt, Inverter Ixt, Bleeder Bxt, ESM
I2t and Motor I2t models
- Motor Models
- Added PMSM Phasor Diagrams
- Added the following pages
- Added Auxiliary Power Module
(Pro version)
- Adds "Power vs Time" Sequence and Cascaded Power Groups
- Allows for "Cascaded Power Groups" where an Auxiliary Power
Module feeds the DC Bus power to another Power Group (Pro
version)
- Added Kinetic Buffer (Pro
version)
- Kinetic Buffer axis stores and/or absorbs energy in a rotating
disc to help manage the DC bus during a mains supply loss
- Model a machine to come to a controlled stop or continue
running through an intermittent loss of power
- Added new concpet of Operating
Modes
- Added Backup Power
Mode, allowing for users to define a specific sequence when the
mains supply power fails
- Supply Peak Power
Optimization (Pro version)
- Added full support for Energy Storage Modules to find the
minimum supply peak power including constant supply power when
possible
- Changed from Peak Factor to absolute Max Supply and Max Regen
values
- Added Regen Peak Power so can control Supply and Regen power
flow separately
- Added new solution Type: "Lowest Pmax with No Regen"
- Added Target Bus Voltage range [Vt0 - Vt1], where previously
there was only Vt0
- Cart Mechanism
- Added new tab called "Traction"
- Added new concept using "Spring Normal Force" or suspension for
the driven wheels. When using the Spring Normal Force, the Applied
Traction Force is not used
- Added the option to include the Applied Traction Force in the
Radial Force calculations [Fr] for gearbox output bearing
sizing
- Moved Lever Arm and other friction inputs under the "Traction"
tab
- The Gravity force for the Radial Force calculation now uses the
Percentage Weight Over Driven Wheels instead of equally
distributing the weight across all wheels
- Added check if No. Driven Wheels > No. Wheels
- Dual Rack & Conveyor
Mechanism
- Updated images on Main and Mechanism forms, Print Report and
Help page
- Re-organized formulae on Help page so easier to understand
- Calculation results remain unchanged
- Extended Project View Only
Mode
- Performance charts now viewable in "View Only Mode" for Power
Groups, Motors, Transformations, Gearbox, Gearbox Shaft Loads,
Actuators and Mechanisms.
- This allows users with less capable feature sets view to more
detailed performance data from projects created by Advanced and Pro
versions. Further, this change allows vendors to better support
their customers when using their Pro version to better
size/optimize a customer's Manufacturer version project, that can
then share with their customer.
- Sequence Shaft Loads
- Added X2 & Y2 offsets for each move segment that are used
to calculate the tilting moment at the adjacent gearbox output
- Allows for much more detailed tilting moment calculations for
sizing gearbox output stage bearings
- Power vs Time form
- Display "Bus Voltage" profile when no Energy Storage
Solution
- Added DC Bus Power Profile, and moved the Bus Energy Y Scale to
the right side of the chart
- Add Edit Rotary Motor form
- Added support to generate AM parameters based on nameplate data
and Mn & nN
- Move form
- Added "Motoring at standstill" checkbox
- Provides the option to specify the mechanism is "Motoring",
meaning that it is applying the Thrust/Torque/Force, and therefore,
the efficiency is [1/n]
- When unchecked, the mechanism efficiency is [n]
- Optimizer PRO
- Added new optimization target, Motor I2t, allowing the
optimizer to minimize the motor's I2t
- Print Dialog
- Add checkbox "Include Page Numbers" to either include or
exclude page numbers in the header and footer. This was requested
so vendors can generate a "partial" report with some but not all
pages in the original report and include only what they need
without causing confusion about excluded pages. "Include Page
Numbers" is enabled by default when creating the initial print
report.
- Vendors tables
- Now allow up to 2000 characters in the [Address] field, to
allow multiple office locations
- Added support for Product Zone variables - Z1, Z2, Z3, etc. -
where one zone can be defined by one or more other zones.
- Eg. "Z3: Z1, Z2, 826", which means the countries in Z1 and Z2
as well as the UK.
- Note that the ProductZones supported since v4.0 - v4.3 are also
supported for backwards compatibility. Only when "Z" is used, is
v4.4 format assumed.
- Gearbox Sizing
- Added support for resonance frequency as part of sizing
rules
- Database
- Gearboxes
- Added Typ = 10 = "Strain Wave Gear"
- Added Typ2 = 4 = "Hollow Bore Flange"
- Added Lh2type = 3 = "HD" that uses Operating Factor (fw)
- Added new column "Torsional Rigidity for Resonance Frequency
calculation" [Ctf2]
- Added new column "Bearing pitch circle diameter at output"
[dp2]
- System Check
- When field weakening is applied to the motor, the message
"Field weakening applied to the motor" is displayed. Now added to
this message "Contact vendor for the drive configuration parameters
needed for field weakening"
- Added new "Help" column, where when the help icon is displayed,
indicates the associated help topic is available by clicking on the
help icon
- License Activation Wizard
- Added "Save to File" button to save a license request to a text
file that can be emailed to the license server
- ACT NW License Servers:
- Now support ACT NW licenses in addition to DGL NW
- This makes Network License Servers (NWLS) easier to configure
as Virtual Machines since there is no need to connect to a physical
dongle plugged into a USB port
- ACT license mechanism is bound to the h/w & s/w signature
of the server, and expires at the License Ends date
- Installer
- Windows 32-bit no longer supported
- Help
- Added new pages
- Cart Mechanism
- Added clarifying note that the Applied Traction Force [Ftr] is
"a clamped force, for example in rail systems"
- Added several detailed diagrams and text to explain how the
traction and friction forces are calculated
- Dual Rack & Conveyor
Mechanism
- Updated image and re-organized formulae so easier to
understan
- Linear Motor
Mechanism
- Added "Total Travel Distance" section explaining how this value
is used
- System Requirements
- Changed Minimum Requirements from Windows 7 64-bit to Windows
10 64-bit
- Added Windows 11 support
- Increased to 8GB RAM minimum and 16GB RAM recommended
- Common Tasks
- Organized "Common Tasks" into subfolders
- Organize Infeed, Bleeder, Capacitor, ESM and APM modules in
"Bus Modules" folder
- Leitachse-Folgeachse Modus ergänzt (Pro version)
- Im Leit-/Folgeachse Modus wird
die Bewegung jeder Folgeachse mit Bezug auf die Position der
Leitachse definiert
- Basiert auf einem virtuellen Master mit Modulo-Distanz und
Zeit
- Unterstützt Master Sequenzen mit konstanter Geschwindigkeit und
auch variable Sequenzen für dynamische Szenarien wie
Max-Stop-Modus
- Optimizer PRO (Pro version option)
- Optimiere
Leit-/Folgeachse ergänzt, womit eine ganze Leistungsgruppe im
Leit-/Folgeachse-Modus optimiert werden kann. Dabei kann der Master
mit konstanter Geschwindigkeit definiert sein oder mit einer
variablen Sequenz.
- Neue Optimierungsziele „Versorgungs-Spitzenleistung“ und
„Versorgungs-Dauerleistung (Auslastung)“ hinzugefügt.
(Leit-/Folgeachse)
- „Auslastung der Leistungsgruppe“ als Randbedingung hinzugefügt
(Leit-/Folgeachse)
- Neue Randbedingungen für Transformation, Motor, Umrichter,
Einspeisung und Bremswiderstand hinzugefügt
- Kommandozeilenschnittstelle (Option für die Pro
version)
- Die Kommandozeilenschnittstelle
ist eine neue Option, die mit der Pro-Version bestellt werden kann.
Sie ermöglicht einem externen Optimierungstool, SERVOsoft zu
steuern und nutzt dazu die Funktion Sequence Auto Update
- Das externe Tool kann ein Profilgenerator sein, ein Programm,
Tabellenkalkulation oder ein Optimierungstool, das die Sequenz
schrittweise anpasst
- Added Command Line Print to File (Pro version)
- The Command Line Print to
File allows other tools to command SERVOsoft to generate print
reports of existing project files
- Supported file formats are PDF and TXT
- Optimierung der Versorgungs-Spitzenleistung (Pro
version)
- Optimierung der
Versorgungs-Spitzenleistung eignet sich für Leistungsgruppen
mit Zwischenkreiskopplung
- Die Sollspannug auf dem Zwischenkreis und die Reduzierung der
Spitzenleistung der Einspeisung werden kombiniert, um die
Einspeise-Spitzenleistung an der Netzversorgung zu
optmieren/reduzieren/anzupassen
- Datenbank für Transformationen
- Die Datenbank für Kupplungen wurde erweitert zur Datenbank für
Transformationen. Dadurch können auch eigene ‚Getriebe‘ und ‚Riemen
und Scheibe‘ in der Datenbank gespeichert werden
- Künftig können weitere Typen von Transformationen wie Wellen,
Rutschkupplungen, Bremsen etc. ergänzt werden
- Lineare Aktuatoren
- Transfomationen für ‚Lineare Aktuatoren‘ werden unterstützt,
wobei die Transformation von jedem Typ sein kann, einschließlich
‚Getriebe‘ und ‚Riemen und Scheibe‘
- Transfomationen für ‚Motor + Lineare Aktuatoren‘ werden
unterstützt, wobei die Transformation von jedem Typ sein kann,
einschließlich ‚Getriebe‘ und ‚Riemen und Scheibe‘
- Hauptseite
- Wenn zum Max-Stop-Modus gewechselt wird, wird der Benutzer
gefragt, ob alle Sequenzen in den Max-Stop-Modus kopiert werden
sollen, wenn die Max-Stop-Sequenzen leer sind
- Die Funktion "Teilen / Kombinieren" für kombinierte Produkte
wurde hinzugefügt, um sie in separate Produkte aufzuteilen und zu
einem Produkt zu kombinieren. Gilt für Getrieberitzel,
Transformations-Linearantriebe, Motorpumpen, Motor-Linearantriebe,
Getriebemotoren, Antriebsmotoren und Antriebsgetriebemotoren
- Sequenz-Seite
- Unterstützung für Export / Import-Ladeformel hinzugefügt
- Zusätzliches Profil „Belastungsleistung“, welches die Leistung
darstellt, die auf die Last einwirkt
- Formular Bewegung
- Für alle Bewegungen wird jetzt die Startzeit bzw. die
Startposition der Leitachse sowie die Startposition der Achse
dargestellt
- Erlaube jetzt Segmente mit "Geschwindigkeit Null
Frequenzweiche"
- Lastkraft / Drehmoment
hinzugefügt, ein Vektor, der von der Bewegungsrichtung unabhängig
ist
- Sequenzwellenlasten (Fr,
Fa, rUL, mUL) hinzugefügt (nur für Rotierend verfügbar)
- Education, Lite und Manufacturer Versions
- Leistungsflußdetails im System
- Die dargestellte mechanische Leistung ist jetzt die Leistung an
der Last, d.h. die Leistung, die benötigt wird, um die Last zu
bewegen.
- Bei Servopumpen ist es die hydraulische Leistung.
- Bis einschließlich Version 4.2 bezogen sich die Leistungswerte
auf den Eingang der Mechanik
- Schubkurbelmechanik
- Pumpen
- Die Mechanik „Motor-Kupplung-Pumpe“ wurde umbenannt in
„Motor-Pumpe“, weil die meisten Hersteller keine Kupplung
verwenden. Wenn eine Kupplung eingebaut ist, wird die Mechanik als
„Motor-Kupplung-Pumpe“ angezeigt.
- Unterstützung von mehreren Pumpen nebeneinander und mehreren
Motor-Pumpen nebeneinander
- Antriebe & Bremsmodule
- Unterstützung von mehreren externen Bremswiderständen pro
Antrieb
- Formular Leistung über der Zeit
- Für Anwendungen mit Einzelachsen wurde eine Ausklappliste für
die Achsen ergänzt, um schnell die Anzeige der Profile der
gewählten Achse hervorzuheben
- Diagramme
- Mit STRG + Drehen am Mausrad kann jetzt in allen Diagrammen
hinein-/herausgezoomt werden
- Installationsprogramm
- Hilfe
- Neue Seiten hinzugefügt
- Motordrehmoment über der
Zeit
- Im Abschnitt Motorkurven wurde der Bereich Feldschwächung
hinzugefügt
- Ballastmodul
- Details für die Formel des Bxt-Überlastmodells im Abschnitt
Berechnung hinzugeügt
- Optimizer
- Die Seite wurde überarbeitet mit den neuen zusätzlichen
Randbedingungen für Transformationen, Motor, Umrichter, Einspeisung
und Bremswiderstand
- Verbesserte Bedienung
- Auf vielen Seiten aufklappbare Bereiche erstellt um sie zu
gliedern und den Leser zu führen
- Verbesserte Anzeige von „Tips“ und einigen „Anmerkungen“ um zu
verdeutlichen, ob eine Funktion in bestimmten Versionen verfügbar
ist
- One install package and one program for all versions and
license types (ACT/DGL/TS)
- When the program starts, it finds all licenses
- If more than one license is found, then the user is prompted to
choose a license
- Project View Only Mode:
- Added "Project View Only Mode" when opening a project using
features not enabled in current version. The Main form is
essentially locked down so the user can see the project layout and
general performance values on the Main form. Otherwise all other
features are locked/disabled. The user still has the option to open
the project as before with the disabled features' inputs
removed.
- Rotary Mechanism:
- Added Position Based Load (Pro version) where users
can import a table of Position, Inertia, Thrust & Torque, where
Torque is a vector
- Options form:
- Added Text Size Factor to increase or decrease the text size
throughout the entire program
- Main form & Project Structure
- The ADVANCED and PRO versions now allow multiple Motors,
Transformations, Gearboxes and Linear Actuators as well as multiple
Drives, Infeed, Bleeder and Capacitor Modules in parallel in the
same axis/slot (1-6)
- The Axis view now shows the Drive Bus, Chopper & Bleeder
performance in addition to the Inverter performance values
- Added support to double-click the large images on the Main form
as same short cuts when double-clicking the tree nodes
- Pumps:
- Added support for Variable Displacement Pumps
- Added "Flow Leakage" and "Power Loss" profiles in Sequence
Chart
- Added "Mean Flow Leakage" and "Mean Power Loss"
- Now chart dP vs Q on the X scale because Q is largely
proportional to speed
- Sequence form:
- Increased Sequence Maximum Segments from 500 to 2000 for the
EDUCATION, LITE and all Manufacturer versions
- Bleeder Calculations:
- Added Bxt overload thermal model
- Drive & Motor Performance Chart:
- Added chart toolbar button to show 1 or 2 Quadrants
(Advanced, Pro versions) more...
- When the chart Crosshairs are enabled and the user right-clicks
to snap the Crosshairs to the nearest data point, now the segment
is highlighted and a tooltip also appears with information about
the data point, allowing the quick detailed analysis of all
torque/force vs speed performance charts.
- Rotary & Linear Motors:
- Added [VbusMax] field, which is the "Max allowed DC bus
threshold voltage"
- System Check uses VbusMax to ensure the motor is not connect to
a bus voltage above what is allowed. Specifically, the check is if
the DC bus Threshold Voltage > VbusMax, then a System Check
alarm occurs.
- [VbusMax] can also be used in database selection to filter
motors below, above a max voltage limit.
- Combined Products Database form:
- Added 'Check Combinations' report for "sub-Models" in the
Combined Products table. After the report runs, two new columns are
added, identifiying any "sub-models" that do not exist in the main
tables, along with the specific details of the missing data. For
example, for a Gear Motor, perhaps the motor model does not exist
in the Motors table. This report was created to address this issue.
Works for all combinations including Drive Motors, Motor Linear
Actuators, Motor Coupling Pumps, Gearbox Pinions, etc. A similar
report was also added to the Database Utility. This goes a
long way in helping vendors manage their product data in the
SERVOsoft database.
- Optimizer PRO:
- Added Sequence "Auto Update", which allows an external tool to
set the Axis Sequence and read performance values. The external
tool can be a profile generator and/or an optimizing tool that
adjusts the Sequence with each iteration. more...
- Energy Storage Modules:
- All rated and performance values are displayed as solution
total values. So if 2x DSMs in the solution, then max rated current
is 2x 60A = 120A. This applies everywhere including the Main form
and Database Selection form, Charts, Print Report, etc.
- Added support for I2t overload model for KOCH ESMs
- Added support for multiple DLC banks connected in parallel
- Added MaxCurrent, ContCurrent and I2t monitoring for Expansion
Modules when Imax, Icont and Imax_tOL are provided
- Motors:
- Added support for Motor Brake On/Off control to be defined in
the Sequence more...
- Added support for up to 3 motor brakes for 1 motor. Previously,
only 1 motor brake was defined with a motor
- Main form:
- Added support to name Power Groups
- Added support to Disable Power Calculations for any
Axis/Slot
- Cart Mechanism form:
- Added Rolling Resistance Coefficient Lever Arm selection
table
- Added Wheel Flange and Slide Friction selection table
- Slider Crank mechanism:
- Added support for Radial Load Force at Crank
- Sequence form:
- Display diagram of a Flying Shear mechanism when the chart
crosshairs are selected using the 'Flying Shear' template
- Added option to display the Motor Brake On/Off profile in the
Sequence Chart
- Database forms:
- Added extensive error checking to give feedback on most filter
errors. This minimizes the need for the last resort message
"Invalid query inputs" when an unknown filter error occurs
- Print Configuration
- Print Configuration settings saved in project file
- Project Configuration
- ADVANCED version increases from 5 to 9 axes
- PRO version increases from 40 to 50 axes
- Multiple Power Groups (Pro version)
- Up to 3 Infeed Modules per Power Group
- Up to 3 Bleeder Modules per Power Group
- Up to 3 Capacitor Modules per Power Group
- Energy Storage Modules for KOCH Products more...
- DES, DEV & DEK products
- DSM & DLC (super capacitors) products
- (Advanced, Pro and some Manufacturer versions)
- Optimizer Pro:
- Added 'Motor Peak Torque Margin' target, which optimizes to a
target margin value
- Added support for 'complex splines' with up to 3 different
profile types in one spline
- Added two new constraints - 'Start Accel = End Accel' and
'Start Jerk = End Jerk'
- Added 'Curve Fitting' more...
- Optimizer works within the drive, motor, gearbox, and/or
mechanism rated curve(s)
- And then generates the resulting motion profile at the
load
- Mechanisms
- Two Servo Pumps driven by one Motor (Pro
version) more...
- Servo Pump (standard in Pro version, was an Option in
v3)
- Ball Screw Database (Lite, Advanced & Pro
versions)
- Cart Mechanism (Advanced & Pro
versions) more...
- Sequence form:
- Added option to display the motor current phasors, Iq & Id
(Pro version)
- Display diagram of the Rotary mechanism when the chart
crosshairs are selected
- Display diagram of a Rotary Knife mechanism when the chart
crosshairs are selected using the 'Rotary Knife' template
- Quick Import
Sequence (Advanced & Pro versions)
- Import Sequences:
- Added support to import 'Time, Velocity and Accel' table
data
Move form:
- Added "Accel Capped" feature, which calculates Start & End
Jerk values to minimize the maximum acceleration for the Poly1-7
profile
- Database forms:
- Re-order columns, set grouped columns, and then save as the
"Default View"
- Performance Improvements:
- Further improved the calculation performance up to 3.5x wrt
v3.3
- Further improved thrust and payload formula calculation
performance to 1.6x faster wrt v3.3
- Project files open 20% faster, and some large project files
open as much as 5x faster wrt v3.3
- Project files use compression algorithm resulting in 2-8x
smaller file size
- Utilization bars on all forms and print report
- Language Options:
- Enabled all language options French, Italian, Spanish, Turkish
& Chinese in addition to the standard language options English
& German (Education, Lite, Advanced & Pro
versions)
- When loading a project, if products are not found, now wait
until the entire project is loaded, and then provide a list of all
products that are not in the database.
- Then users can select which products to be added to the
database.
- By default, all products are checked.
- This is much more organized and more manageable, especially for
large projects with 20-50 axes and perhaps 100 products that may
not be in the local database.
- Runs as 64-bit application on Windows 64-bit, allowing for
better performance for large projects
Verwandte Themen